Intrinsically safe circuit and high frequency alternating current frequency is higher than the industry -- ignition characteristic
Release time:2015/4/16 11:37:33Views:5336

Technical science and now known as the "intrinsically safe" explosion-proof measures of standard sources, the two can be traced back to the coal mine gas dangerous area of the use of electrical devices. Commissioned by the Prussian mine gas Committee based test, in Aachen (Aachen Industrial University in 1886, 1898 in BVS for the follow-up tests still conclude: "every electric spark are able to cause an explosion." It is a basic research on the basis of the explosion of the Senghenydd coal mine explosion in October 14, 1913 (which led to the death of 439 people) by Wheeler. The study identified communication and instrumentation in the spark ignition limit laid the foundation for the test. This study results as the basis to formulate the British standard BSl259:1945. So far, the study result still is quote in full to the ATEX Directive 94 / 9 / EC requirements of the essential health and safety requirements in the test, the results show that in. Huilin and BVS, director of Pailin as a result of the close cooperation study, even in the VDE0170:1926 on provisions of the equipment can not be caused by explosion of sparks limit value.

1.Test device for DC power and industrial alternating current
The experimental apparatus used by Wheeler has been improved in many countries and has been further developed. In the UK, the device for "Brealdlash No.3"; in France, "Kclateur Rapide" and intrinsically safe test for national standards. According to reports, the Russian the device is with a rifle bullet shattered conductors and circuit interrupting Sparks - coincidentally, with the German proposal to wire avulsion, the same effect. Very early on to try to make the test program in the IEC technology level of international standardization. In 1967 during the IEC31G committee meeting, Prague, through the comparison of different test conclusions submitted, decided to a group of staff development by Siemens company in Berlin test device, test results. In the recording of the meeting, the circuit parameters are limited to 1.5V / 300V / 1H. The whole technical environment of the test device developed based on experience is the aim of the DC circuit or industrial AC circuit, which is usually used to control and measure the circuit.
At that time, used in hazardous locations of the device. There is no denying the fact that also had indeed used higher frequency. For example: for capacitance measurements or by keying frequency control (TFSK) method for data transmission. Subsequently, handheld wireless phones and other high frequency applications, but in this regard, the application of security is mainly related to power supply circuits and auxiliary capacitors and coils. In general, the decision not to carry out high-frequency components related to high frequency energy analysis.
Understanding of spark test device: the device in 1965 after standardization to join / 0171 VDE0170 and 1977 after standardized with the EN50020 and for inspection of intrinsically safe circuit.
The most important milestone is of cable and wire effect (for example: the research carried out by the Schebsdat, caused by the inductance ignition process of, for example: by Vogt research and Johonnsmeyer ignition spark energy conversion case with actual mutual influence of basic instructions, caused by a capacitor ignition process research.
To improve the repeatability of the test results and the adaptability of large current, the best treatment plan is put forward. For the applicability of the method, the special instructions (provision) for the upper bound (upper limit of the cut-off frequency) are avoided. At first, in this regard not caused too much to worry about, but with the increase of the use of radio equipment, with more high frequency were energy transmission, and taking into account the special industrial sites. For example: radio transmitter near the refinery, the problem exposed gradually.

2.Press IEC 60079 - 11 as a spark test device for a spark generator
The total test design idea is: in a conductor circuit and two conductor short circuit, spark is generated, this way contact, a contact and mutual movement and power under worst case conditions possible and with high return rate, anywhere may sparks. By the simple circuit ignition limit of a variety of published curves and comparing the gas air mixture minimum ignition energy of the known values, we can in test conditions can be derived using the spark test device circuit and the energy of the corresponding value. At this point, for example, in the excitation coil through to DC, the spark in the conversion of storage can often only 50%, and the other half consume in the power of resistance, the contact spring assembly of electric sensor and contact spring assembly itself.
In the circuit with the coil, the fact that the spark is formed during the contact break point and the break point is selected for the optimum value of the input to the spark energy. Finally, due to the increase of the induced voltage, the longer time to suppress the rapid removal of each other. The original design of the spark test apparatus, which clearly shows that the design was originally used for the DC power supply circuit test.

3.In the frequency range up to 100kHz, the intrinsically safe circuit power transmission
Early results show that when the frequency of the AC circuit is high, the electrical parameters of the required electrical parameters are increased. Because of this effect, showing obvious increase in the frequency of about 100kHz, is transmitted by high frequency of energy. The relationship between the intrinsically safe transmission and high frequency is initially by proposed in the basic principles of intrinsically safe power supply project, and later with the BVS in "high-frequency intrinsically safe power transmission limit determination of research" project get to be confirmed by further studies.

 

To share:
About Company profile The Leader Organization Enterprise Honor
Culture Staff Activities Business Philosophy
News Enterprise News Industry News
Product Product Series Application
Support Service System Knowledge Marketing Network Download
Resources Talent Strategy Staff development Recruitment
Contact Contact Message Board
chat
Copyright ? 2015www.rcartoon.com.cnALL RIGHTS RESERVED
To share:
Address:Shenyang Xinmin Lama Industrial Park
主站蜘蛛池模板: 欧美不卡视频在线 | 三级毛片一 | 黄免费观看 | 给我免费观看片在线观看中国 | 欧美特黄aaaaaaaa大片 | 人人九九精品 | 国产传媒懂得 | jizz日韩 | 日日摸日日碰夜夜爽无 | 国产精品视频yy9299 | 色播久久人人爽人人爽人人片av | 香蕉97视频观看在线观看 | 天天操夜夜操天天干 | 精品国产一区二区三区久久久蜜月 | 最近中文字幕完整视频高清 | www.日韩色 | 黄色a区| 学生的妈妈3在线 | 午夜电影中文字幕 | 特殊的职业2免费看 | 国产乱国产乱老熟300部视频 | 免费观看美女用震蛋喷水的视频 | 国产精品久久久久久久久鸭无码 | 综合亚洲AV图片区 | 国产成人精品电影 | 少妇挑战黑人高潮惨叫 | 绿巨人www在线观看 狠狠色婷婷久久一区二区三区91 | 国产成人综合亚洲专区 | 国产护士在线观看 | 91视频网页版 | AV不卡秒播在线观看 | 亚洲综合久久无码色噜噜 | 亚洲成a人片77777国产 | www干| 国产日产欧美一区二区 | 亚洲一区亚洲二区 | 第一136av福利视频导航 | 一起草视频在线播放 | 日本做爰大片免费观看一 | 国产亚洲va综合人人澡精品 | 亚洲国产午夜片 |